HP GRAPHITEContact us phone images

Use instructions of graphite electrodes

Use instructions of graphite electrodes 

The electrode holder must be located within the two white warning lines. The contact surface between the holder and electrode shall be frequently cleaned, to keep the good contact with the electrode. The water leakage is strictly prohibited in the cooling water jacket of holder. 

01.

Before connecting the electrode, its threads shall be firstly cleaned up, and when the nipple is carefully screwed in one end of electrode, the lifting nipple shall be screwed in the other end thereof, without colliding the thread. It is not recommended that, the nipple is directly installed on the electrode being used on the furnace.   

pre-caution-for-using-electrode-001

02.

The steel wool or metal brush and abrasive cloth are not allowed to clean up the threads of electrode, but the compressed air free of oil and water can be used only.   

                                                                          .

how to use graphite electrode 002

03.

he rotatable elastic hook shall be used, and the soft support pad shall be put below the electrode nipple, to prevent from damaging the thread.   


how to use graphite electrode 003

04.

efore connecting the electrode, its hole shall be cleaned up with the compressed air free of oil and water.   

 

how to use graphite electrode 004

05.

The electrode shall be lifted and conveyed on the furnace with the elastic hook for centering, slowly moved down, slightly screwed in, and then, tightened with shroud ring.                                                           .

how to use graphite electrode 005


06.

The shroud ring is screwed with special calipers according to the specified torque, and either mechanical or hydraulic way is adopted. The air pressure equipment shall be screwed to the specified torque.                          .

how to use graphite electrode 006


07.                    .

No contact between the sections of two electrodes or too big contact pressure will affect the normal use of electrode. Please refer to the torque specified in the Figure.                               .


QQ截图20180615173648.png
how to use graphite electrode 007

09.

To avoid the electrode from breaking off, the insulating materials shall not be provided in the furnace. The working current of electrode shall be adapted to the allowable current of electrode in the Instructions.                              

how to use graphite electrode 009

10.

To avoid the electrode from breaking off, the block materials should be placed at the bottom of the electrode, and the small materials should be placed at the top thereof.                                                                                     